Why do you need the real-time radiation monitoring power of the RaySafe i3?

Staff exposure to radiation due to the increasing use of minimally invasive, image-guided medical procedures continues to grow, but so does awareness of the need for rules and regulations governing the maximum dose of radiation allowed.

These factors have led to the development of different detection devices designed to keep staff safe, including real-time staff dose monitoring systems.

Fill out the form to speak to a representative today!

We regret that the current U.S. Export Regulations prohibit the sale of our products to U.S. embargoed countries. We must, therefore, decline any request for our products.

After submitting this form you will receive an email to confirm your email subscription.

Monitor staff radiation exposure with the RaySafe i3: Real-Time Personal Radiation Dosimetry

The RaySafe i3 system is the latest generation of the RaySafe radiation dosimetry family. As part of the RaySafe commitment to building a better radiation safety culture, we are proud to offer this real-time monitoring system that helps medical staff proactively monitor their radiation exposure and adapt their behavior to minimize unnecessary risk.

The system includes a set of the new RaySafe i3 real-time personal radiation dosimeters coupled with a display and software to provide a complete, immediate visual of radiation exposures.

Here's how the i3 works:

The real-time display shows dose data for connected dosimeters instantly. Green, yellow and red bars indicate the dose rate for each individual user; accumulated dose is displayed next to the bars. By tapping your name, more detailed information about your personal dose history can be accessed.

RaySafe i3 System

Figure 1. 1: Dosimeter Rack, 2: Real-time Dosimeter, 3: Real-time Display, 4: Dost Viewer software.

The dosimeter records X-ray radiation and communicates with the Real-time Display via radio. The dose rate is presented in real time on the display as does rate bars: green, yellow or red, depending on the intentsity.

Tap a dosimeter row on the Real-time Display to get more details.

To view measurements stored in a dosimeter, connect the dosimeter to a computer running Dost Viewer. Dost Viewer can also be used for changing dosimeter settings, such as name and annual dose limit.

Radiation measurements are simultaneously stored for post-procedure analysis, facilitating continued awareness and learning, as well as enabling long-term comparisons over time, between both labs and users.