ESA609 Firmware v1.01
Download
This firmware fixes calculation of the Line-to-Neutral voltage measurement
Requirements
ESA614/615 Test Results Converter
Download
The ESA614/615 Test Results Converter changes the proprietary files into .CSV file-type and displays these in a simplified Test Report format for easy archiving and further conversion to .pdf for better security.
ProSim SPOT Firmware v1.09
VT650/900/900A Firmware v2.04
Download
User Oxygen Calibration should be performed after updating.
Service calibration not required.
Plugin
Ansur BP Pump 2 Plug-In v1.0.3.1
Download
Ansur Plug-In module to control the BP Pump 2 Non-Invasive Blood Pressure Simulator.
Ansur ESA601 Plug-In v1.1.4
Download
Ansur Plug-In module to control the ISA601 Electrical Safety Analyzer.
Ansur ESA612 Plug-In v1.1.3
Download
Ansur Plug-In module to control the ESA612 Electrical Safety Analyzer.
NOTE: Ansur Executive v2.8.4 or higher is required for this plug-in.
Ansur ESA615 Plug-In v1.0.5.1
Download
Requires Ansur Executive v3.0 or below.
Ansur ESA615 Plug-In v1.1.2
Ansur ESA620 Plug-In v1.2.6
Download
Ansur Plug-In module to control the ESA620 Electrical Safety Analyzer. Requires Ansur Executive v3.1.3 and firmware v2.10 or higher.
Ansur IDA-4 Plug-In v1.0.1
Download
IDA-4 Plus Ansur Plug-In module to control the IDA-4 Plus Infusion Device Analyzer.
Ansur IDA-5 Plug-In v1.0.5
Download
Ansur IDA-5 Ansur Plug-In module to control the IDA-5 Infusion Device Analyzer.
Ansur Impulse 4000 Plug-In v1.0.2
Download
Ansur Plug-In module to control the Impulse 4000 Defibrillator / Pacer Analyzer.
Ansur Impulse 6000D/7000DP Plug-In v1.2.5
Download
Requires Ansur Executive 3.1.3 or higher. Allows selection of VFIB2 Coarse and VFIB2 Fine ECG waveforms for Energy measurement, Charge Time, and Arrhythmia Wave tests. Updated VFIB waveforms to VFIB1, but kept backward compatibility for existing Ansur templates and test records. Corrected some formatting issues in test reports. Ansur Plug-In module to control the Impulse 6000D Defibrillator Analyzer and Impulse 7000DP Defibrillator / Pacemaker Analyzer.
Ansur INCU-II Mini Plug in v1.1.0
Download
Mini Plug-In module for the INCU-II Incubator/Radiant Warmer Analyzer.
Includes Excel Add-in v1.8 to allow data from the INCU-II to be downloaded to your computer to view results and create/modify/print reports.
Ansur Index 2 Plug-In v1.0.5
Download
Ansur Plug-In module to control the Index 2 Pulse Oximeter Simulator.
Ansur Lagu Plug-In v1.6.1.1
Download
Ansur Plug-In module to control the Iagu Infusion Pump Tester.
Ansur ProSim 8 Plug-In v1.0.3
Download
Requires Ansur Executive v3.0 or below. Ansur Plug-In module to control ProSim 8 Vital Signs Simulator. NOTE: When PC is logged in with username other than administrator, Ansur ProSim8 Mini may not work properly. Ansur or ProSim Mini should be run as administrator to avoid the error. Right click (by pressing and holding SHIFT key in the keyboard) on the Ansur or ProSim8 Mini Plug-In icon on desktop or start menu and select Run as administrator.
Ansur ProSim 8 Plug-In v1.1.5
Download
Requires Ansur Executive v3.1.3 or above.
Ansur QA ES III v1.0.8 Plugin
Download
Ansur Plug-In and mini Plug-In module to control the QA-ES III Electrosurgical Analyzer.
Requirements
Requires firmware v1.03 or newer.
Ansur QA-1290 Plug-In v2.0.0.1
Download
Ansur Plug-In module to control the QA-1290 NIBP Simulator.
Ansur QA-4X Plug-In v2.3.1
Download
Ansur Plug-In module to control the QA-40 Defibrillator Analyzer and/or the QA-45 Defibrillator/Transcutaneous Pacemaker Analyzer.
Ansur QA-90 Plug-In v2.2.3
Download
Ansur Plug-In module to control the QA-90 Mk II Electrical Safety Analyzer.
Ansur QA-ES Plug-In v1.4.7
Download
Ansur Plug-In module to control the QA-ES Mk II Electrosurgical Analyzer.
NOTE: Ansur Executive v2.7.0 or higher is required for this plug-in.
Ansur QA-ST Plug-In v2.2.2
Download
Ansur Plug-In module to control the QA-ST Electrical Safety Analyzer.
Ansur QA-VTM Plug-In v2.2.1
Download
Ansur Plug-In module to control the QA-VTM Ventilator Tester.
Ansur QED 6 Plug-In v1.0.3
Download
Ansur Plug-In module to control the QED 6 Difibrillator Analyzer.
NOTE: Ansur Executive v2.7.0 or higher is required for this Plug-In.
Ansur VT Plug-In v2.1.12
Download
Ansur Plug-In module to control the VTPlus HF, VT305 and VT Mobile Gas Flow Analyzers.
Standard
ESA612 Data Viewer Software
Download
Free software allows you to connect the ESA612 Electrical Safety Analyzer to your PC and download test records.
Requirements
• Windows® 2000, XP, or Vista
• Microsoft .NET Framework 2.0
Hydrograph Software (This version: 3.50)
Download
Windows compatible graphics software for IDA-1S and IDA-5 infusion device analyzers to control unit, display results and print results via PC.
VT+ HF/VT Mobile Graphics Software
Download
Windows-compatible graphics software for VT PLUS HF and VT MOBILE results-printing from PC.
VT900/VT650 Excel Add-In 1.00
Download
Windows-compatible Excel software for VT900 & VT650.
Requirements
Communication Interfaces
ESA612/615 Communications Interface
Download
This document specifies the communications interface version 1.2 for the ESA612/615 Electrical Safety Analyzers
ESA614 Communications Interface
Download
This document specifies the communications interface version 1.0 for the ESA614 Electrical Safety Analyzer.
ESA620 User Communication Interface v1.0
IDA-5 User Communication Interface v1.0
Impulse 6000D/7000DP Communications Interface v2.4
Download
The Impulse 6000D and Impulse 7000DP can be controlled remotely through its Computer Port: a USB Interface port that looks like a COM port to a personal computer (PC). You can control the Impulse by sending commands to it and receiving responses, including test data, through the COM port.
INCU II User Communication Interface v1.0
ProSim 8 Communications Interface v3.17
Download
This document specifies the communications interface for the ProSim 8 patient simulator. The ProSim 8 can be controlled remotely by sending it commands receiving responses, including test data.
QA-ES III User Communication Interface v1.1
Download
This document specifies the communications interface for the QA-ES III Electrosurgery Analyzer.
The QA-ES can be controlled remotely by sending it commands and receiving responses.
VT900A_VT650 User Communication Interface v8.0
Download
This document specifies the communications interface for products in the Ventilator Tester (VT) family including models VT900A, VT900, and VT650.
The VT can be controlled remotely by sending it commands and receiving responses, including test data.
Firmware Update
ESA614/ESA615 Firmware Upgrade
Download
ESA614 / ESA615 firmware v3.01 does not require recalibration if upgraded from v2.12. Older firmware MUST be calibrated when upgrading to activate improvements to differential leakage measurements. Instructions are included in the zip file
Requirements
Ansur Executive 2.9.7 and Ansur ESA615 Plugin 1.0.5.1 or later
ESA620 Firmware Upgrade
Download
Instructions are included in the zip file. Note: Install this latest firmware version only if your firmware is 2.10 or above. For older versions of firmware, please have the unit serviced by Fluke Biomedical for an upgrade.
Impulse 7000 Firmware v2.12
Download
Impulse 6000D/7000DP Firmware
Requirements
Ansur Executive 3.1.3 (or later) and Ansur Impulse 7000 Plug-In 1.2.5 (or later) Windows
INCU II Firmware Upgrade v1.07C
Download
Requirements
Ansur Executive 3.0
WARNING: Install v1.07C only if your serial number is 35999999 or below.
INCU II Firmware Upgrade v1.09
Download
INCU II Firmware Upgrade v1.09 WARNING: Install v1.09 only if your serial number is 36000000 or higher.
Requirements
Windows
Ansur Executive 3.0
ProSim 8 Firmware v2.09
Download
Requirements
Ansur Executive Ansur ProSim 8 Plugin
QA-ES III HF Leakage Firmware 1.04 Update App Note